Process cooling
Industrial Water Chillers — Mining Applications
Air-cooled industrial water chillers, 4 kW to 750 kW, rated for 45 °C ambient — 52 °C on request.

Overview
About Industrial Water Chillers — Mining Applications
Our air-cooled industrial water chillers cover 4 kW to 750 kW of cooling capacity. They are rated to operate comfortably in 45 °C ambient environments, and 52 °C is achievable on request.
In keeping with the demanding requirements of the mining industry, the chillers have lockable IP rated electrical enclosures, external cable protection and ELV controls.
For large capacity cooling, the FS-S range is designed to produce very large volumes of cold water for critical applications such as mill presses, safety showers and waste product cooling.
Projects
Coal loading plant — Queensland.
Nickel mining — Queensland.
Rated for 45 °C ambient
Comfortable operation in 45 °C ambient environments; 52 °C achievable on request.
Built for mine sites
IP66 rated enclosures with lockable panel handles, steel wire armoured external cabling and ELV control circuit and external parts.
Integrated pumps
Integrated primary water pumps, with buffer tanks from 75 to 450 L across the TC range.
Controllers to suit site spares
A choice of controllers to suit the spares you already hold, and a highly accurate electronic controller.
The range
Types and configurations
Each of these is a distinct engineering answer. Tell us the duty and we'll tell you which one belongs on your plant.
TC series
TC03 to TC160, 3.3 to 175 kW cooling capacity, with plate heat exchanger evaporators to TC50 and shell and tube from TC55.
FS-S large capacity series
FS-S-200 to FS-S-750, 210 to 766 kW cooling capacity, for very large volumes of cold water.
Close tolerance
Hot gas bypass valve or compressor VFD for close temperature tolerance — standard tolerance of ±0.5 °C achievable depending on load.
Redundancy
Tandem / N+1 arrangements, redundant duty-cycled pumps and a pump UPS terminal set so cold water keeps flowing if the 3-phase supply fails.
Corrosive and hazardous sites
Coated coils and stainless steel cabinets for coastal salt spray and sulphur-bearing mine sites. Where flammable gas is present an Ex or ATEX rated unit may be required.
Site options
BMS connectivity, potable water supply, remote condensers, soft starters, castors, high ambient construction and compressor VSD.
Specifications
From the datasheet
Figures as published on the Thermal IQ datasheet for this range — the specific model is confirmed at selection against your operating conditions.
- Cooling capacity
- 4 kW to 750 kW range
- TC series
- TC03 to TC160: 3.3 to 175 kW (10 °C water supply, 45 °C ambient)
- FS-S series
- FS-S-200 to FS-S-750: 210 to 766 kW
- Ambient rating
- 45 °C; 52 °C on request
- Refrigerant
- R134a
- Compressor
- Scroll, direct-on-line start
- Evaporator
- Plate HX (TC03–TC50); shell and tube (TC55–TC160)
- Buffer tank
- 75 to 450 L (TC series)
- Condenser
- Copper tube and aluminium fin, no microchannel — 7 mm rifle bore tube, 14 FPI, nano (blue fin) coating, head pressure fan speed control
- Control circuit
- 24 VDC, ELV
- Electrical panel
- IP66, lockable panel handles
- Water connections
- 1" to 2½" FBSP (TC series)
- Chassis
- Powder-coated galvanised steel; welded hot-dipped galvanised frame on units over 80 kW
12-month warranty, issued by Thermex Solutions
- 12 months from the agreed commissioning date — no later than 30 days from the invoicing date.
- The warranty is to the first purchaser of the unit.
- It covers all parts and labour to rectify the unit.
- Subject to Thermex Solutions' full terms and conditions, provided at the time of order.
Applications
Where it's used
- Mill presses
- Safety showers
- Waste product cooling
- Remote, high ambient mine sites
Materials
- Galvanised steel
- Copper tube
- Aluminium fin
- Stainless steel cabinet (option)
Manufacturing partner — Mammoth
Mammoth HVAC — part of Nortek Systems, Oklahoma, USA — is a leading manufacturer of complete HVAC packaged systems and one of Thermal IQ's manufacturing partners.
Gallery
In the workshop and on site
Questions
Mining Chillers FAQs
How hot can it be on site?
The chillers are rated to operate comfortably in 45 °C ambient environments, and 52 °C is achievable on request.
What capacities are available?
4 kW to 750 kW of cooling capacity — the TC series from 3.3 to 175 kW and the FS-S large capacity series from 210 to 766 kW.
What makes them suited to mining?
Lockable IP66 electrical enclosures, steel wire armoured external cabling, an ELV control circuit, coil protection on all models, and options for corrosive environments, redundant pumps and pump UPS.
How tight can the water temperature be held?
With the close tolerance option — a hot gas bypass valve or a VFD on the compressor — a standard tolerance of ±0.5 °C is achievable depending on load conditions.
Related
Often specified alongside
Shell & Tube Heat Exchangers
Shell and tube condensers, evaporators and water-to-water exchangers, from 10 kW to 1,250 kW across the listed series.
Hot Water Heat Pumps — Air to Water
R134a air-to-water heat pumps from 5 to 200 kW heating capacity, for water temperatures up to 65 °C.
Plate Heat Exchangers — Gasketed
Gasketed plate heat exchangers for HVAC and industrial duties, from full vacuum to 64 bar and 0 to 225 °C.
Next step
Get a selection — Mining Chillers
Send the duty — flows, temperatures, fluids and pressures — and we'll return a selection sheet, drawing and price. If a different technology suits you better, we'll tell you that too.