Heat pumps
CO₂ Heat Pumps
R744 high temperature air-source heat pumps — water out at 40 to 95 °C, running in ambients from −35 to 45 °C.
Overview
About CO₂ Heat Pumps
Our CO₂ high temperature heat pumps use the natural refrigerant R744 — ODP 0 and GWP 1 — to produce outlet water from 40 °C up to 95 °C from inlet water between 5 °C and 55 °C.
They are air-source machines rated for ambient temperatures from −35 °C to 45 °C, for stable, reliable operation in a wide range of regions.
The CO₂ integrated heating and cooling unit produces 7 °C chilled water, or lower-temperature antifreeze fluid, while also producing high-temperature hot water — with a comprehensive energy efficiency of up to 10.0.
Natural refrigerant
R744 (CO₂) with an ODP of 0 and a GWP of 1.
High outlet water temperature
Outlet temperature range 40 °C to 95 °C; inlet temperature range 5 °C to 55 °C.
Low ambient operation
Suitable for ambient temperatures from −35 °C to 45 °C.
Heating and cooling together
The integrated unit provides 7 °C chilled water or lower-temperature antifreeze fluid while producing high-temperature hot water.
The range
Types and configurations
Each of these is a distinct engineering answer. Tell us the duty and we'll tell you which one belongs on your plant.
CO₂ high temperature heat pumps
Seven air-source models, MRPAS-30SHDC3A to MRPAS-320DHDC3A, from 28.4 to 319.0 kW heating capacity at the normal temperature condition.
CO₂ integrated heating and cooling units
Chilled water at 7 °C (or lower-temperature antifreeze fluid) and high-temperature hot water from one machine, with comprehensive energy efficiency up to 10.0.
Specifications
From the datasheet
Figures as published on the Thermal IQ datasheet for this range — the specific model is confirmed at selection against your operating conditions.
- Refrigerant
- R744 (CO₂) — ODP 0, GWP 1
- Heating capacity
- 28.4 to 319.0 kW, COP 4.60 to 4.63 (20 °C dry bulb, 15 °C water in, 55 °C water out)
- High-temperature outlet
- 24.0 to 284.0 kW, COP 3.50 to 3.55 (20 °C dry bulb, 15 °C water in, 80 °C water out)
- Water inlet temperature
- 5 °C to 55 °C
- Water outlet temperature
- 40 °C to 95 °C
- Ambient temperature
- −35 °C to 45 °C
- Compressor
- CO₂-dedicated semi-hermetic piston
- Heat exchangers
- Copper tube fin (air side), double-tube (hot water side)
- Design pressure
- 14.0 MPa high side, 8.0 MPa low side
- Power supply
- 380 V / 3N~ / 50 Hz
- Sound power
- ≤60 to ≤78 dB(A) across the range
Applications
Where it's used
- HVAC and refrigeration
- Power generation
- Marine
- Process applications
- Food preparation
- Renewable energy
- Data centre cooling
Materials
- Copper tube fin
- Double-tube water heat exchanger
Manufacturing partner — Mammoth and RVG
Thermal IQ has partnered with Mammoth and RVG, internationally recognised HVAC manufacturers with extensive operations across the United States and China — combining local engineering knowledge with world-class manufacturing capability.
Questions
CO₂ Heat Pumps FAQs
Why use CO₂ as the refrigerant?
R744 is a natural refrigerant with an ODP of 0 and a GWP of 1, and it produces high-temperature hot water — up to 95 °C outlet on these units.
How cold can it be outside?
The air-source CO₂ heat pumps are suitable for ambient temperatures from −35 °C to 45 °C.
Can one machine heat and cool?
Yes — the CO₂ integrated heating and cooling unit provides 7 °C chilled water or lower-temperature antifreeze fluid while producing high-temperature hot water.
How is this different from your air-to-water hot water heat pumps?
They are different machines. The CO₂ units run on R744 and deliver water up to 95 °C. The air-to-water hot water heat pumps run on R134a and deliver water up to 65 °C, in a 5 to 200 kW range.
Related
Often specified alongside
Hot Water Heat Pumps — Air to Water
R134a air-to-water heat pumps from 5 to 200 kW heating capacity, for water temperatures up to 65 °C.
Water Tanks
Thermal energy storage, buffer, commercial hot water (calorifier), indirect and boiler feedwater tanks.
Brazed Plate Heat Exchangers
Compact brazed plate heat exchangers for heating, cooling, evaporation and condensing — 6 to 200 plates.
Next step
Get a selection — CO₂ Heat Pumps
Send the duty — flows, temperatures, fluids and pressures — and we'll return a selection sheet, drawing and price. If a different technology suits you better, we'll tell you that too.