Heat pumps
Hot Water Heat Pumps — Air to Water
R134a air-to-water heat pumps from 5 to 200 kW heating capacity, for water temperatures up to 65 °C.

Overview
About Hot Water Heat Pumps — Air to Water
Our air-to-water hot water heat pumps cover 5 to 200 kW of heating capacity. They run on R134a refrigerant for high water temperatures — up to 65 °C.
Every unit has IP66 rated enclosures, sturdy powder-coated galvanised steel construction, hot gas injection evaporator protection and a highly accurate PLC controller. A master controller can run up to eight heat pumps together, and integrated primary water pumps are available for process heating.
We are expanding into heat pumps and heat transfer solutions so we can offer our expertise for the coming electrification of water heating across industry.
R134a to 65 °C
Refrigerant chosen for high water temperatures, up to 65 °C.
IP66 as standard
IP66 rated enclosures, external cabling protected with steel wire glands, segregated voltages and coil protection on all models.
Up to 8 units, one controller
A master controller is available to control up to 8 heat pumps.
Controllers to suit site spares
A choice of controllers to suit the spares you already hold on site.
The range
Types and configurations
Each of these is a distinct engineering answer. Tell us the duty and we'll tell you which one belongs on your plant.
TH08 to TH26
8 to 26.8 kW heating capacity, coaxial condensers.
TH30 to TH150
31 to 160 kW heating capacity, shell and tube condensers.
BMS connectivity
Low-level dry contacts for master run and master fault; high-level Modbus, SNMP and BACnet over Ethernet without a gateway.
Tandem / N+1
Wired so the lead unit manages duty cycling and keeps control if a fault develops in one of the heat pumps.
Potable water supply
Heat pumps can be manufactured to deliver water for potable water applications.
Corrosive environments and soft starters
Coated coils and stainless steel cabinets for coastal and sulphur-bearing mining sites; compressor soft starters where the power supply is not robust.
Specifications
From the datasheet
Figures as published on the Thermal IQ datasheet for this range — the specific model is confirmed at selection against your operating conditions.
- Heating capacity
- 5 to 200 kW range
- Listed models
- TH08 to TH150: 8 to 160 kW (45 °C water supply, 20 °C ambient, 65% RH)
- Refrigerant
- R134a
- Water temperature
- Up to 65 °C
- Compressor
- Scroll, direct-on-line start
- Condenser
- Coaxial (TH08–TH26); shell and tube (TH30–TH150)
- Air-side coil
- Copper tube and aluminium fin, no microchannel — 7 mm rifle bore tube, 14 FPI, nano (blue fin) coating
- Fans
- Axial, 450 to 630 mm
- Water connections
- 1" to 2½" FBSP
- Control circuit
- 24 VDC
- Electrical panel
- IP66
- Chassis
- Powder-coated galvanised steel; welded hot-dipped galvanised frame on units over 80 kW
12-month warranty, issued by Thermex Solutions
- 12 months from the agreed commissioning date — no later than 30 days from the invoicing date.
- The warranty is to the first purchaser of the unit.
- It covers all parts and labour to rectify the unit.
- Subject to Thermex Solutions' full terms and conditions, provided at the time of order.
Applications
Where it's used
- Building hot water supply, with master and booster heat pumps charging storage tanks
- Process heating, with integrated primary water pumps
- Potable hot water (potable water supply option)
- Multi-unit plant with a master controller for up to 8 heat pumps
- Coastal and mining sites (corrosive environment option)
Materials
- Powder-coated galvanised steel
- Copper tube
- Aluminium fin
- Stainless steel cabinet (option)
Questions
Air-to-Water Heat Pumps FAQs
How hot is the water?
The R134a refrigerant is selected for high water temperatures — up to 65 °C.
What sizes are available?
5 to 200 kW heating capacity. The listed TH models run from 8 kW (TH08) to 160 kW (TH150) at 45 °C water supply and 20 °C ambient.
Can several heat pumps run together?
Yes. A master controller can control up to 8 heat pumps, and units can be wired for tandem or N+1 operation so the lead unit manages duty cycling.
Can it connect to our BMS?
Yes. Low-level connectivity is dry contacts for master run and master fault; high-level connectivity is Modbus, SNMP and BACnet over Ethernet without a gateway.
How is this different from your CO₂ heat pumps?
They are different machines. These air-to-water units run on R134a and deliver up to 65 °C. The CO₂ heat pumps run on R744 and deliver outlet water from 40 °C up to 95 °C.
Related
Often specified alongside
CO₂ Heat Pumps
R744 high temperature air-source heat pumps — water out at 40 to 95 °C, running in ambients from −35 to 45 °C.
Water Tanks
Thermal energy storage, buffer, commercial hot water (calorifier), indirect and boiler feedwater tanks.
Industrial Water Chillers — Mining Applications
Air-cooled industrial water chillers, 4 kW to 750 kW, rated for 45 °C ambient — 52 °C on request.
Next step
Get a selection — Air-to-Water Heat Pumps